• Increase font size
  • Default font size
  • Decrease font size
GentleYAG

Candela - GentleYAG

ApplicationsSpecificationsTechnologiesBefore & After PicturesFrequently Asked QuestionsResearch Articles


Applications:

The GentleYAG effectively treats all skin types, including tanned skin, offering unmatched treatment capabilities in permanent hair reduction, leg veins, facial veins, wrinkles and skin tightening. Treat patients year-round with GentleYAG's 1064 nm wavelength, multiple spot sizes, variable pulse durations and Candela's patented cryogen cooling system (DCD™) for maximum patient comfort and safety.

Hair

  • Permanent hair reduction on all skin types
  • Beard Bumps (PFB)

Skin Rejuvenation

  • Skin Tightening
  • Wrinkles

Vascular

  • Facial Veins
  • Leg Veins

Top of Page


Specifications:

 

GentleYAG

GentleYAG Limited Edition

GentleYAG SRT

GentleYAG HR

GentleYAG VR

Laser Type

Nd:YAG laser

Nd:YAG laser

Nd:YAG laser

Nd:YAG laser

Nd:YAG laser

Wavelength

1064 nm

1064 nm

1064 nm

1064 nm

1064 nm

Repetition Rate

Up to 10 Hz

Up to 10 Hz

Up to 10 Hz

Up to 2 Hz

Up to 2 Hz

Pulse Duration

0.250-300 ms

0.25-100 ms

0.250-300 ms

3-300 ms

100-300 ms

Spot Sizes (diameter)

 

12 mm
8 mm
3 mm

6 mm
8 mm
10 mm

12 mm
15 mm
18 mm

1.5 mm
3 mm

Fluence Range

Up to 600 J/cm2

Up to 460 J/cm2

Up to 200 J/cm2

Up to 70 J/cm2

Up to 600 J/cm2

Beam Delivery

Lens-coupled optical fiber with handpiece

Lens-coupled optical fiber with handpiece

Lens-coupled optical fiber with handpiece

Lens-coupled optical fiber with handpiece

Lens-coupled optical fiber with handpiece

Pulse Control

Fingerswitch,
Footswitch

Fingerswitch,
Footswitch

Fingerswitch,
Footswitch

Fingerswitch,
Footswitch

Fingerswitch,
Footswitch

Dimensions

35”H x 16”W x 28” D
(89 cm x 41 cm x 71 cm)

35”H x 16” W x 28” D
(89 cm x 41 cm x 71 cm)

35”H x 16” W x 28” D
(89 cm x 41 cm x 71 cm)

35”H x 16” W x 28” D
(89 cm x 41 cm x 71 cm)

35”H x 16” W x 28” D
(89 cm x 41 cm x 71 cm)

Weight

210 lbs (95 kg)

210 lbs (95 kg)

210 lbs (95 kg)

210 lbs (95 kg)

210 lbs (95 kg)

Electrical

230 V 50 /60 Hz, single phase, 16A

230 V 50/60 Hz, single phase, 16A

230 V 50/60 Hz, single phase, 16A

230 V 50/60 Hz, single phase, 16A

230 V 50/60 Hz, single phase, 16A

Top of Page


Technologies:

The GentleYAG is the fastest and most powerful Nd:YAG laser on the market today. It effectively treats all skin types, including tanned skin, offering unmatched treatment capabilities in permanent hair reduction, leg veins, facial veins, and wrinkles. Treat patients year-round with GentleYAG's 1064nm wavelength, multiple spot sizes, variable pulse durations and Candela’s patented cryogen cooling system (DCDtm) for maximum patient comfort and safety.

Fast – With unprecedented 18 mm spot size and repetition rates up to 2 Hz, the GentleYAG offers fast treatment times with fewer laser pulses.

Powerful - 26,333 watts of peak power and capable of delivering fluences up to 600 J/cm² for vascular applications, and hair removal energies in pulse durations as short as 3 ms for unparalleled treatment efficacies.

Treats all skin types - Deep penetration with minimal scattering of laser energy makes the GentleYAG ideal for all skin types, especially dark and tanned skin.

Versatile – Non-ablative treatment, including fine lines and wrinkles, and for pseudofolliculitis barbae (PFB), or beard bumps, leg and facial veins.

Patented Epidermal Cooling - Candela's Dynamic Cooling Device represents an adjustable epidermal protection technology to maximize patient safety and comfort.

 

Top of Page


Before & After Pictures:

Check out dramatic before and after photography documenting GentleYAG’s treatment efficacy and versatility! 

Hair Removal Treatment

Vascular Treatments

Top of Page


Frequently Asked Questions

Q: How does the laser work?

A: The laser creates a beam of high-intensity light that penetrates deep into skin tissue where it delivers a controlled amount of therapeutic heat. For patient comfort, the Dynamic Cooling Device (DCD) technology protects the upper layers of the skin with a cooling burst of cryogen. Together the long-pulse laser and DCD cooling offer optimal treatments with minimal side effects.

Q: What conditions can be treated?

A: The laser will remove facial and body hair, vascular lesions, pigmented lesions, and wrinkles.

Q: What does the treatment include?

A: Depending on the area treated, the procedure varies from patient to patient. Generally, the treatment will include: wearing safety eyewear to protect the practitioner and patient's eyes from the laser light during the procedure. A small hand piece will be used that touches the skin to deliver the laser light. A light spray of coolant onto the skin will be felt just before each laser pulse. A test area will be done prior to the entire treatment. Most patients experience little discomfort at the treatment site because of the dynamic cooling device. The degree of discomfort varies with each person, depending on his/her pain threshold. Topical anesthesia may also be requested based on individual preferences or tolerances. The procedure can take as little as 10 minutes or up to an hour, depending on the area treatment. The treated area may become pink or red within 30 minutes of treatment; this may last from a few hours to several days and is relieved with the application of ice or cooling gels.

Q: What precautions should be taken before and after treatment?

A: Avoid the sun 4-6 weeks before and after treatment. Hair removal patients must avoid electrolysis, plucking or waxing hair for 6 weeks prior to treatment. If there is a history of per oral herpes, prophylactic antiviral therapy may be prescribed. Photosensitive drugs must be discontinued 3 to 5 days before treatment.

Q: How many treatments will be needed?

A: The number of treatments depends on the treatment require and the condition of the skin. For hair removal, most patients require 4 to 6 treatments, as the process is only effective when the hair follicle is in its active growth stage. Other conditions require anywhere from 2 to 6 treatments. Many factors impact the efficacy of individual treatments, including the severity of the condition being treated.

Q: What are the side effects?

A: Risks are minimal. Side effects may include purpura (a laser bruise), redness, blistering, hyperpigmentation, hypo pigmentation and swelling in the treated area. These side effects usually do not last for more than a few days. Permanent side effects such as hyperpigmentation or hypo pigmentation or scarring are rare.

Q: Is this procedure covered by insurance?

A: Most insurance companies do not offer reimbursement for cosmetic procedures. However, consult with your insurance carrier for more information.

Top of Page


Research Articles:

  • GentleYAG Clinical Bulletin #13
    "Treating Leg Veins with the GentleYAG® Laser 3 mm Spot" by Dr. Marguerite Germaine. According to Dr. Germain, the GentleYAG is the best laser for treating leg telangiectasias.
  • GentleYAG Clinical Bulletin #14
    "Treating Facial Veins with the GentleYAG® Laser 1.5 mm Spot" by Dr. Mitchell Chasin. Dr. Chasin explains his preferred approach treating facial veins with the GentleYAG’s 1.5 mm spot.
  • GentleYAG Clinical Bulletin #15
    "Tissue-Tightening Satisfaction with the GentleYAG" by Dr. Suzanne Yee. Dr. Yee promotes the advantages of GentleYAG skin tightening treatments versus RF or IR technologies.
  • GentleYAG Clinical Bulletin #16
    "Hair Removal for Dark Skin Types with the GentleYAG" by Dr. Eliot Battle. In his bulletin, Dr. Battle states that the GentleYAG finally enables him to deliver laser hair removal treatments to people of color that match the laser treatment experience of lighter skin types.

Top of Page